Full automatic self cleaning filter housing system Full automatic back washing filter housing BCM series BCM full automatic back washing filter housing is suitable for filtering high flow, high speed, low viscosity fluid particle impurity. BCM full automatic back washing filter housing is a...
What is filter housing?
Full automatic self cleaning filter housing system
Full automatic back washing filter housing BCM series
BCM full automatic back washing filter housing is suitable for filtering high flow, high speed, low viscosity fluid particle impurity.
BCM full automatic back washing filter housing is a mechanical and electrical products, with advantages of reasonable design, high filtration efficiency, low operating costs, continuous filtration in back washing process, etc., which is widely used in metallurgy, chemical, electric power, oilfield injection water, ballast water, environment-friendly water treatment, etc..
Working principle of BCM full automatic back washing filter housing:
The filtered liquid is flowing from the inlet to the filter housing, then going through the fixing plate into the filter housing, the liquid flows from the filter element inside to the outside, and then flows out from the filter vessel outlet; Impurities produced from back washing filter flows out from the sewage outfall.
Advantage
Application
Sea water desalination, circulating cooling water and oilfield re-injection water, ballast water for ship, boiler reuse water, Ultra filtration ,back osmosis filtration, ion exchange pre-treatment, Paper nozzle filter.4.Filter equipment control system is sensitive, accurate operation, and can flexibly adjust the differential pressure and time setting value of back washing based on different water and filter accuracy.
Design Parameter Table | |||||||
NAME: Full automatic back washing filter housing BCM series | |||||||
MODEL: BCM300F100EDB | |||||||
Design Data | Code&STD. | GB150.1~150.4-2011 Reference GB150.1~150.4-2011 《Pressure Vessels》 | |||||
Design Press. | (Mpa.g) | 1.0 | Mat'of Man Parts | S30408 (GB 24511-2009) | |||
Design Temp. | (℃) | 80 | Corr.Allow. | (mm) | 0 | ||
Hydro. Test Press. | (Mpa.g) | 1.25 | Filter Element Material | SS 304 | |||
Filte Area. | (㎡) | 0.81 | Gasket Material | NBR | |||
No. Filter Element | 7 | Full Capacity | (m³) | 0.06 | |||
Filter Element Size | (mm) | CartridgeΦ70*580 | Empty Weight | (kg) | ~120 | ||
Clean Pr.Drop | Mpa | 0.01 | Max.Allowed Pr.Drop | Mpa | 0.1 | ||
Technical Data According to the user data tables or after consultation to fill in | |||||||
Flow Rate. | (m³/h) | / | Fluid. | / | |||
Working Temp. (in/out) | (℃) | / | Fluid Performance | / | |||
Working Press. | (Mpa.g) | / | Fluid Density | (kg/m³) | / | ||
Pore Size. | (μm) | / | Viscosity | (cp) | / | ||
Solid Content. | (WT%) | / | |||||
NOZZLE LIST | |||||||
Mark | Size | PN | Connections Standard | Flange Type | Face Type | Service | From q |
N1 | DN100 | 10 | HG/T20592-2009 | PL | RF | Inlet | |
N2 | DN100 | 10 | HG/T20592-2009 | PL | RF | Outlet | |
N3 | DN40 | 10 | HG/T20592-2009 | PL | RF | Drain | |
N4 | 1/2" | / | Rc1/2"(male) | / | / | Vent | |
N5 | 1/4" | / | Rc1/4"(female) | / | / | Pressure Guage | |
N6 | 1" | / | R1"(male) | / | / | Drain | |
P1、P2 | 1/4" | / | Rc1/4"(female) | / | / | Differential pressure |